Rs485 (-106), Rs485, Canner – Metrologic Instruments VOYAGERGS MS9590 User Manual

Page 12: Nstallation

Advertising
background image

8

S

CANNER

I

NSTALLATION

RS485

“

(-106)


1. Turn off the host device.

2. Plug the 10-pin RJ45 end of the

MVC cable into the 10-pin socket
on the scanner. There will be an
audible click when the connector
lock engages.


3. Connect the other end

‹

of the MVC

cable to the host device.


4. Turn on the host device.

5. The blue LED on the scanner will

turn on, the white LED will flash, and
the scanner will beep once.


6. Scan the bar code below to activate

the RS485 interface.

³

9

9

9

9

9

5

USB is the default communication protocol for an MS9590-106 and the
MS9591-106. If the recall defaults bar code is scanned after the unit
has been configured for RS485, the scanner will revert to the USB
default communication protocol. The bar code above will need to be
rescanned to return the unit to the RS485 communication protocol.

The scanner is shipped from the factory configured to set of default
conditions. Plugging the scanner into a port on the host system does
not guarantee that the scanned information will be communicated
properly to the host device. The scanner and host device must use the
same communication protocol. Please refer to the MetroSelect Single-
Line Configuration Guide or the help files provided with MetroSet2 for
instructions on changing the scanner’s factory default configuration.

See caution on page 6.

“

Applicable for IBM

®

host applications

‹

The type of host connection available on an MVC cable is application dependent.
Contact a customer service representative at 1-800-ID-METRO for additional information
on the MVC converter cable series.