OM-491 Page 14

4-3. Mounting Welding Generator

Ref. 190 250-A / Ref. 802 169-A

Y Do not weld on base. Weld-

ing on base can cause fuel

tank fire or explosion. Weld

only on the four mounting

brackets or bolt unit down.

1

Mounting Bracket

2

1/2 in Bolt And Washer (Not

Supplied)

3

3/8-16 x 1 in Screws

(Supplied)

To Bolt Unit In Place:
Remove hardware securing the

four mounting brackets to the base.

Reverse brackets and reattach to

base with original hardware.
Mount unit to truck or trailer with 1/2

in (12 mm) hardware (not supplied).
To Weld Unit In Place:
Weld unit to truck or trailer only at

the four mounting brackets.

Tools Needed:

9/16 in

1

1

2

3

Welding Unit In Place

Bolting Unit In Place

4-4. Installing Muffler

Y Stop engine and let cool.

1/2 in

Tools Needed:

Ref. 802 169-A / Ref. 191 631-A

Y Do not blow exhaust toward

air cleaner or air intake.