Connecting work clamp, Connecting input power, 6. connecting work clamp – Miller Electric ICE-12C User Manual

Page 16: 7. connecting input power

Advertising
background image

OM-2248 Page 12

4-6.

Connecting Work Clamp

802 463-A

1

Work Clamp

2

Workpiece

Connect work clamp to a clean,
paint-free location on workpiece, as
close to cutting area as possible.

1

2

4-7.

Connecting Input Power

802 460-B

Check input voltage available at
site.

1

Grounded 120 VAC
Receptacle (Non-CE Models)

A 120 volt, 20 ampere individual
branch circuit protected by
time-delay fuses or circuit breaker
is required (see Section 4-1).

2

Plug From Unit

Select extension cord of 12 AWG
for up to 53 ft (16 m).

3

Grounded 230 VAC
Receptacle (CE Models)

A 230 volt, 10 ampere individual
branch circuit protected by
time-delay fuses or circuit breaker
is required (see Section 4-1).

4

Plug From Unit (Customer
Supplied)

Select extension cord of 14 AWG
for up to 133 ft (41 m).

Y

Special installation may be
required where gasoline or
volatile liquids are present −
see NEC Article 511 or CEC
Section 20.

2

1

2

3

4