Troubleshooting power source, 5. troubleshooting power source – Miller Electric ICE-12C User Manual

Page 24

Advertising
background image

OM-2248 Page 20

6-5.

Troubleshooting Power Source

Connect unit to proper input
voltage. (see Section 4-7).

Yes

No

Is input power
connected to
correct line
voltage?

Is Power
switch in the
On position?

Place Power switch in the
On position. (see Section
5-1).

No

Yes

Is the cooling
fan running?

Check Power switch S1,
relay CR2, and thermistor
R1.

No

Yes

Is Power light
On?

Reset Power switch S1 and
verify line power voltage.
Check relay CR2, thermistor
R1, and Control board PC1.

No

Yes

Is Trouble
light On?

Check torch consumables.
Reset Power switch S1. If
unit is overheated, wait
while fan cools down unit
temperature.

No

Yes

Press torch trigger and
listen for compressor
operation. Check for
Postflow air at torch. Check
Control board PC1,
compressor filter, and
compressor connections to
PC1 and torch.

Yes

No

Is compressor
operating?

Press torch trigger and
check if pilot arc ignites.
Check torch consumables.
*Check torch connections,
relay CR1, compressor, and
torch.

Yes

No

Does pilot arc
ignite?

Place torch near workpiece
and check if pilot arc “jumps”
or transfers to workpiece.
Check work clamp connec-
tion. *Check Control board
PC1 and connections, and
torch and its connections.

Yes

No

Does pilot arc
transfer to
workpiece?

Check all connections,
Check main transformer T1,
Check inductor L1. Return
to beginning of chart.

*Servicing procedure to be performed
only by authorized Service Station.

*

*

*