Warning, 1. routine maintenance, Each use – Miller Electric APT-1000 User Manual

Page 12: Every week, 3 months

Advertising
background image

OM-1572 Page 6

SECTION 5 – MAINTENANCE & TROUBLESHOOTING

ELECTRIC SHOCK can kill.

Do not touch live electrical parts.

Turn Off power source, and disconnect input power
before inspecting, maintaining, or servicing.

HOT PARTS can cause severe burns.

Allow cooling period before maintaining or servicing.

Maintenance to be performed only by qualified persons.

WARNING

swarn8.1* 2/93

5-1.

Routine Maintenance

Turn Off all power before maintaining.

Each Use

Check

Torch Tip,

Electrode,

And Shield

Cup

Check

Torch Tip

Shutdown

System

Every Week

Check

Air/Gas

Pressure

Tape

Torn

Outer

Covering

– –

Clean

And

Tighten

Torch

Connections

3-2

Torch Body

Air/Gas Hose

Torch Cable

– –

Replace
Cracked

Parts

3 Months

Power

Source
Manual

See

Section

5-2

Power

Source
Manual

ST-127 899-A

Figure 5-1. Maintenance Schedule