Warning, 3. troubleshooting – Miller Electric APT-1000 User Manual

Page 14

Advertising
background image

OM-1572 Page 8

Figure 5-2. Checking Detector Pins And Checking/Replacing Shield Cup, Tip, And Electrode

5-3.

Troubleshooting

ELECTRIC SHOCK can kill.

Do not touch live electrical parts.

Turn Off power source, and disconnect input power
before inspecting, maintaining, or servicing.

HOT PARTS can cause severe burns.

Allow cooling period before maintaining or servicing.

Troubleshooting to be performed only by qualified
persons.

WARNING

swarn8.1* 2/93

Table 5-1. Cutting Trouble

Trouble

Remedy

Section

Sparks come out top of cut, or cut is not
clean.

Torch travel speed too fast; reduce travel speed.

Figure 4-2

Check torch tip and electrode, and replace if necessary.

5-2

Metal being cut is too thick; increase power source Thickness
control setting.

*

Arc goes out while cutting.

Make sure torch tip is touching metal while cutting.

Figure 4-2

Be sure work clamp is securely attached.

*

Arc goes on and off while cutting.

Torch travel speed is too slow; increase travel speed.

Figure 4-2

Check torch tip and electrode, and replace if necessary.

5-2

*See power source Owner’s Manual.

Advertising