Replacement procedure, wiring & testing of parts – Majestic Appliances MJ9950 User Manual

Page 12

Advertising
background image

12

Replacement Procedure, Wiring & Testing of Parts



1) Power Switch (52799)


Replacement Procedure:

Unplug the unit.

Remove the top panel (Two screws behind and slide back)

Pull out the soap dispenser, plastic washer knob and dryer knob.

Remove the control panel. (3 Screws)

Pull out the plastic switch cover for the power switch.

Pull out the power switch by matching the grooves in the panel pushing the switch

towards the back.

Replace with the new switch and do the wiring as before / below.

Fix all the parts back by following the reverse procedure.


Wiring: Power switch - bottom view







Testing Procedure:

Cold Test:

1) When the Power button is pushed in – There will be continuity between the connectors
1 & 3, 2 & 4.



112

114

111

113

1 2

4

3