11) Thermostat (00808)


Replacement Procedure:

Unplug the unit.

Remove the top panel (Two screws behind and slide back)

The fusible link is located on the heater housing as shown in the figure.

There is a small fuse inside the covering held by the clamp crewed on the housing.

Unfix the screw and replace the same and do the wiring as before / below.

Fix all the parts back by following the reverse procedure.


Wiring: Thermostat










Testing Procedure:

Cold Test:


1) Check the continuity between the two terminals with black dots and the two terminals
with the red dots, if there is continuity the thermostat is good.







FE