English – Middleby Marshall PS555G GAS User Manual

Page 12

Advertising
background image

12

ENGLISH

SECTION 2 - INSTALLATION

plies with the Standard for Quick-Disconnect Devices for Use

With Gas Fuel, ANSI Z21.41 (in U.S.A.), or, if applicable, Quick-

Disconnect Devices for Use With Gas Fuel, CAN1-6.9 (in

Canada).

C. Gas Conversion
Where permitted by local and national codes, it is possible to

convert ovens from natural to propane gas, or from propane to

natural gas. Use the appropriate Middleby Marshall Gas

Conversion Kit for the specific oven model.
CAUTION
The terms of the oven's warranty require all start-ups, conver-

sions and service work to be performed by a Middleby Marshall

Authorized Service Agent.

Figure 2-15 - Flexible Gas Hose Installation

To Gas

Supply Pipe

90°

Elbow

Union OR quick-

disconnect device

Flexible

Gas Hose

Full-Flow

Gas

Shutoff

Valve

90°

Elbow

Figure 2-16 - Gas Burner and Piping Assembly

Modulating

gas valve

Pilot pressure tap

(where pilot gas

pressure is measured)

Combination Gas

Control Valve

(Safety Regulator)

Gas Burner

Burner

Blower

Inlet pressure

tap (where

incoming gas

pressure is

measured)

Manifold pressure tap

(where manifold gas

pressure is measured)

On/Off Knob

Always leave in

“ON” position

Manual

shutoff

valve

Gas line for

other oven

cavities

Cap for top

oven cavity

Nipple, 1-1/4”

dia. X 3”

(76mm) L, NPT

Elbow, 90°,

1-1/4” dia.

Gas Pipe, 1-1/4”

dia. X 54”

(1372mm) L

B. Connection
Check the oven’s gas supply requirements before making the

gas utility connection. Gas supply requirements are listed on

the oven’s serial plate and in Table 1-3, Gas Orifice and

Pressure Specifications (in Section 1, Description).
Check the serial plate to determine the type of gas (Propane or

Natural) to be used with the oven.
Refer to the instructions in the gas hose package (included in

the Installation Kit) before connecting the gas line. One gas line

connection method is shown in Figure 2-15; however,

compliance with the applicable standards and regulations is

mandatory.
Inlet, regulated, and pilot gas pressure readings can be taken

using a “U” tube manometer at the tap locations shown in

Figure 2-16.
NOTE

The installation must conform with local codes or in the absence

of local codes, with the National Fuel Gas Code, ANSI Z223.1-

latest edition.
In Australia, the installation must conform with AGA Code

AG601 and with any requirements of the appropriate statutory

authority.
CANADIAN:

CAN/CGA-B 149.1 Natural Gas Installation Code

CAN/CGA-B 149.2 Propane Installation Code
Certain safety code requirements exist for the installation of gas

ovens; refer to the beginning of Section 2 for a list of the

installation standards. In addition, because the oven is equipped

with casters, the gas line connection shall be made with a

connector that complies with the Standard for Connectors for

Movable Gas Appliances, ANSI Z21.69 (in U.S.A.), or, if appli-

cable, Connectors for Movable Gas Appliances, CAN/CGA-6.16

(in Canada), as well as a quick-disconnect device that com-

Advertising