Dma timing – Maxtor 5T040H4 User Manual

Page 29

Advertising
background image

AT INTERFACE DESCRIPTION

5 – 4

DMA Timing

DMA Timing

DMA Timing

DMA Timing

DMA Timing

T IMIN G PARAMET ERS

MODE 0

MODE 1

MODE 2

t0

Cycle Ti me ( min)

480 ns

150 ns

120 ns

tC

DMAC K to DMARQ delay

tD

DIOR-/D IOW- (min )

215 ns

80 ns

70 ns

tE

DIOR- data a cce ss (min)

150 ns

60 ns

tF

DIOR- data hold (min )

5 ns

5 ns

5 ns

tG

DIOR-/DIOW- data setup ( min)

100 ns

30 ns

20 ns

tH

DIOW- d ata hold ( min)

20 ns

15 ns

10 ns

tI

DM AC K to DIOR-/D IOW - se tup (min)

0

0

0

tJ

DIOR-/DIOW- to DMAC K ho ld ( min )

20 ns

5 ns

5 ns

tKr

DIOR- neg ated p uls e wi dth (min )

50 ns

50 ns

25 ns

tKw

D IOW - nega ted puls e wid th ( min )

215 ns

50 ns

25 ns

tLr

DIOR- to D MARQ delay (ma x)

120 ns

40 ns

35 ns

tL w

DIOW- to D MARQ de la y (max)

40 ns

40 ns

35 ns

tZ

DMAC K- to tr ista te (max)

20 ns

25 ns

25 ns

Figure 5 - 3

Multi-word DMA Data Transfer

Advertising