Maxtor 5T040H4 User Manual

Page 37

Advertising
background image

HOST SOFTWARE INTERFACE

6 – 2

Sector Count Register

Sector Count Register

Sector Count Register

Sector Count Register

Sector Count Register

Holds the number of sectors to be sent during a Read or Write command, and the number of sectors per
track during a Format command. A value of zero in this register implies a transfer of 256 sectors. A multi-
sector operation decrements the Sector Count register. If an error occurs during such an operation, this
register contains the remaining number of sectors to be transferred.

Sector Number Register

Sector Number Register

Sector Number Register

Sector Number Register

Sector Number Register

Holds the starting sector number for any disk operation. The register is updated as each sector is processed in
a multi-sector operation.

Cylinder Number Registers

Cylinder Number Registers

Cylinder Number Registers

Cylinder Number Registers

Cylinder Number Registers

Two 8-bit Cylinder Number registers (Low and High) specify the starting cylinder for disk operation.

Device/Head Register

Device/Head Register

Device/Head Register

Device/Head Register

Device/Head Register

Used to specify the drive and head number to be operated on during any disk operations. Within the
context of a Set Parameters command, this register specifies the maximum number of heads on the drive.
Bit definitions follow:

7

6

5

4

3

2

1

0

1

LBA

1

DRV

HS3

HS2

HS1

HS0

LBA

Mode

Dr ive

Select

Head

Select

Head

Select

Head

Select

Head

Select

Select LBA Mode – Enabling this bit for commands not supported by LBA mode will abort the selected command. When set,
the Task File register contents are defined as follows for the Read/Write and translate command:

CONTEN TS

LBA BITS

Sector Numb er

0 - 7

Cylinde r Low

8 - 15

C yli nd er Hi gh

16 - 23

D rive /He ad

24 - 27

Drive Select

– Set to 0 to select the master drive; set to 1 to select the slave drive.

Head Select

– Specifies the binary coded address of the head to be selected.

Status Register

Status Register

Status Register

Status Register

Status Register

Contains results of the last command executed, and the drive’s status. The other seven Task File registers may
be read only when bit 7 (BUSY) of the Status register is low. Reading any of the Task File registers when
BUSY is high returns the value of the Status register. Reading the Status register also clears any interrupt
request to the host. Bit definitions follow:

7

6

5

4

3

2

1

0

BUSY

D RDY

D F

D SC

D RQ

0

0

ERR

C ontr oller
Busy

Device
Ready

Device
Fault

Device
Se ek
C omplete

D ata
Reque st

Err or

Controller Busy

– Goes active when a command is written to the Command register, indicating controller

task execution. After a command, this bit resets.

Device Ready

– Indicates that the drive is ready for commands. If drive ready is not present, all commands abort.

Device Fault

– Indicates the drive’s detection of a write fault condition, causing all commands to abort.

Device Seek Complete

– Signifies a seek completion, and that the drive is on track.

Data Request

– Indicates that the drive’s sector buffer is ready for data transfer.

Error

– The Error bit sets when the previous command has completed with a non-recoverable error.

Advertising
This manual is related to the following products: