3. GAS SETTINGS

Regulator pressure must be measured and adjusted before the unit goes into service,
following installation and when operational performance is in question. A soft blue flame,
just short of a yellow tip, gives the best results; combustion air can be adjusted by opening
or closing the air shutter slightly.

4.LIGHTING INSTRUCTIONS

RMB 600 Series Models

without safety pilot

a.) Turn all burners to OFF.

d.) Turn the runner tube valve to ON.

b.) Remove the top grid(s).

e.) Light the runner tube.

c.) Remove the last radiant(s) closest to

Note: If the runner tube does not light, wait a

the side(s) of the unit.

few seconds, then try again.

f.) Replace the radiant(s) and top grid(s).

Push and turn the burner valves to operate the individual burners as needed.

g.) If any burner fails to light from the runner tube, shut off all the burners and the runner

tube. Do not attempt to re-light for five minutes after shutdown. Repeat steps a thru f.
If unit still fails to operate properly, contact authorized service personnel.

Broiler Shut Down

Turn all burners to OFF.
Turn the runner tube valve to OFF.