1. Turn all burners to OFF.
2. Remove the top grid.
3. Remove a radiant.
4. Turn the shut off valve to ON.
5. Press and hold the reset (blue) button on the safety pilot valve. Wait 15–30 seconds. Light the runner

tube. DO NOT release the reset button.

NOTE: If the runner tube does not light, wait a few seconds, then try again.

NOTE: When lighting the runner tube for the first time after connecting the unit to the gas source, the light

time will probably increase to 1–2 minutes.

6. Wait an additional 15–30 seconds. Release the reset button. The runner tube should remain lit.

NOTE: If the runner tube fails to ignite, repeat step 5. If the runner tube fails to ignite after three

attempts, contact an authorized MagiKitch’n service agent.

7. Replace the radiant and top grid.
8. Push and turn the burner valves to operate the individual burners as needed.

Broiler Shut Down

1. Turn the shut off valve to OFF.
2. Turn all burners to OFF.

Off

On

Shut-off
Valve

Safety Pilot Valve
(located under
shelf)

Thermocouple

(located on far
end of runner tube)

Top Grid

Radiant

Reset Button

Safety Pilot Valve

Runner Tube

SMB 600 Series -S Models

with safety pilot

Lighting and shut down of these models is identical to that of the RMB-S models except that there
are no radiants to be removed. Simply light the runner tube by inserting the ignition device through
the gap between the front burner support and the coal support as shown in the lighting instructions
for the SMB 600 Series Models without safety pilot.