Magnetek 144-45117-R3 User Manual

Page 7

Advertising
background image

Regenerative

Power

Module

-

September

2010

144-45117-R3

Page 7 of 20

LED Fault and Status Indicators

LED status indicators provide the following indications:

COLOR MARKING

DESCRIPTION

GREEN POWER

Indicates

that

the brake chopper power supply is

present

GREEN INTERLOCK

Indicates that the external contact is closed when the
interlock is enabled or that the interlock is in the
disabled position

GREEN READY

Indicates that no fault condition exists and that the
external interlock is not open

AMBER ACTIVE

Indicates

that

the brake chopper is conducting

AMBER RESET

Indicates that the reset circuit is activated

RED

OVERTEMP

Indicates that the heat sink temperature has reached
95° C and the module has shut down to protect the
transistor.

RED

IGBT FAULT

Indicates that the module is shut down on short
circuit IGBT detection

TEST Switch

The TEST switch simulates a DC bus voltage increase; this input is used to set the turn on voltage
and verify transistor and resistor functionality.