2 single-phase (phase a, b) connection, Single-phase (phase a, b) connection, Ction 2.4.2.2), or 3) three-phase s – Maretron ACM100 User Manual

Page 10: Acm100 user’s manual, Page 6 revision 1.2, Ac sour ce, A. connect the black wire to pin 7 (i

Advertising
background image

ACM100 User’s Manual

a. Connect the black wire to pin 7 (I

A+

) on the ACM100

b. Connect the white wire to pin 8 (I

A-

) on the ACM100

c. Disconnect the hot wire from the AC power source and place it through the hole in

the Current Sensor such that the arrow on the Current Sensor points towards the AC
power source. Then, reattach the hot wire to the AC source.


Step 3: You must supply a cable for connecting the voltage sense pins on the ACM100 to the
AC source. For the purposes of these instructions, we will assume that the cable has one black
conductor and one white conductor. Install the voltage sense cable as follows:

a. Connect the white wire from one end of the Voltage Sense cable to pin 4 (V

ANeutral

)

on the ACM100.

b. Connect the white wire from the other end of the Voltage Sense cable to the neutral

wire of the AC source being monitored.

c. Connect the black wire from one end of the Voltage Sense cable to pin 1 (V

ALine

) on

the ACM100

d. Connect the black wire from the other end of the Voltage Sense cable to a fuse

appropriately sized for the black wire (18 gauge wire minimum and 3 amp fuse or
less).

e. Connect the other end of the fuse to the AC source hot wire (the fuse should be

placed within 6 inches of the connection to the hot wire).


2.4.2.2 Single-Phase (Phase A, B) Connection

Please refer to Figure 4 for connecting the ACM100 to a single phase, dual line system.

Current

Transformer

Page 6

Revision 1.2

Figure 4 – Single-Phase (Dual Line) Connection Diagram



Use the following instructions when you are connecting the ACM100 to a single-phase circuit
connected via two hot wires. You will need to install two current transformer and two user-
supplied voltage sense cables. The ACM100 comes with a single current transformer so you

V

A

Li

ne

V

A

N

eutr

al

V

B

Li

ne

V

C

Li

ne

V

B

N

eutr

al

V

C

N

eutr

al

I

A+

I

A-

I

B+

I

B-

I

C+

I

C-

Line (Phase A)

Neutral

U.S.

120 Volts

60Hz

+

-

Europe

220 Volts

50Hz

+

-

AC Sour

ce

1 2

5

4

3

6

7

8

9 10 11 12

Fus

e

Current

Transformer

ACM100 Screw Terminals

Fus

e

Line (Phase B)

Advertising