Dca-220ssj/ssju — diagnostic display, 1800 rpm – Multiquip MQ Power Whisperwatt 50 Hz Generator DCA-220SSJ User Manual

Page 26

Advertising
background image

PAGE 26 — DCA-220SSJ/SSJU— OPERATION AND PARTS MANUAL — REV. #1 (01/06/09)

!

!
!

Indicates Auxiliary Gage Fault

Indicates Fault Warning

Indicates Derate or Shutdown Condition Fault

5.

Touching the “Enter Button” will redisplay the hidden
fault. Touching the “Enter Button” once again will hide
the fault and return the screen to the single or four
parameter display. NOTE: The fault can only be cleared
by correcting the cause of the fault condition.

ENGINE OIL PRESSURE

GAGE NOT RESPONDING

1 of x

HIDE

Active Fault Codes

1.

During normal operation the single or four parameter
screen will be displayed.

2.

When the PowerView receives a fault code from an
engine control unit the single or four parameter screen
will be replaced with the “Active Fault Codes” message.

3.

If the word “MORE” appears above the “Arrow Buttons”,
there are more active fault codes that may be viewed.
Use the “Arrow Buttons” to scroll to the next “Active
Fault Code”.

125°F

COOL TEMP

143°F

OIL TEMP

57 PSI

1000 RPM

ENG RPM

OIL PRES

98%

14.2

57 PSI

1000 RPM

LOAD RPM

BATT VOLT

ENG RPM

OIL PRES

SPN110 FMI10

HIGH COOLANT TEMP

WARNING

1 of x

MORE

HIDE

SPN110 FMI10

HIGH COOLANT TEMP

1 of x

MORE

HIDE

4.

To acknowledge and “Hide” the fault and return to the
single or four parameter display touch the “Enter Button”.

5.

The display will return to the single or four parameter
display but the display will contain the “Active Fault”
warning icon. Touching the “Enter Button” will redisplay
the hidden fault.

6.

Touching the “Enter Button” once again will hide the
fault and return the screen to the single or four parameter
display.

7.

The Single or Four parameter screen will display the
fault icon until the fault condition is corrected. NOTE:
Ignoring active fault codes could result in severe engine
damage.

SPN110 FMI10

HIGH COOLANT TEMP

1 of x

MORE

HIDE

COOL

1800 RPM

0

1500

3000

TEMP!

ENG RPM

!

98%

14.2

!

57 PSI

1000 RPM

LOAD RPM

BATT VOLT

ENG RPM

OIL PRES

!

SPN110 FMI10

HIGH COOLANT TEMP

WARNING

1 of x

MORE

HIDE

GO TO 1-UP DISPLAY

ENGINE CONF
SETUP 1-UP DISPLAY
SETUP-4-UP DISPLAY
SELECT UNITS

STORED CODES

G

ADJUST BACKLIGHT

98%

14.2

57 PSI

1000 RPM

LOAD RPM

BATT VOLT

ENG RPM

OIL PRES

!

DCA-220SSJ/SSJU — DIAGNOSTIC DISPLAY