Dca-220ssj/ssju — diagnostic display – Multiquip MQ Power Whisperwatt 50 Hz Generator DCA-220SSJ User Manual

Page 34

Advertising
background image

PAGE 34 — DCA-220SSJ/SSJU— OPERATION AND PARTS MANUAL — REV. #1 (01/06/09)

4.

Touch “Select” to enter the “Gage Data” display. When
“Gage Data” is selected the PowerView will
communicate with the analog gages at a fixed rate of
38.4k Band, 8 data bits, no parity check, 1 stop bits,
half duplex.

5.

Use the “Arrow Buttons” to scroll through the items or
touch “Menu” to return to the “Utilities” menu.

6.

Touch “Menu Button” to return to the “Utilities” menu.

7.

Use the “Arrows” to highlight Remove All Gages”. Touch
“Select” to clear gage data from memory. It takes a
moment to clear all gages.

GAGE DATA

REMOVE ALL GAGES
SOFTWARE VERSION
MODBUS SETUP
FAULT CONVERSION
ADJUST BACKLIGHT
DEMO MODE ON

ADDRESS:20
SOFTWARE REVISION #:
ERRORS:

NONE

1 of x

ENGINE OIL PRESSURE

ADDRESS:20
SOFTWARE REVISION #:
ERRORS:

NONE

1 of x

ENGINE OIL PRESSURE

CLEARING GAGES

PLEASE WAIT

8.

When the gage data has cleared, the display
automatically returns to the “Utilities” menu. Scroll to
“Software Version”. Touch “Select” to view the software
version currently in the diagnostic display.

9.

Touch “Menu” to return to “Utilities”. Highlight Fault
Conversion” using the “Arrows”. Touch “Select” to enter
the Fault conversion menu.

10. Use the “Arrows” to scroll to and highlight the desired

version then touch “Select”. An asterisk denotes which
version is currently selected.

NOTE: There are four (4) different methods for converting
fault codes. The diagnostic display always looks for J1939
Version 4 and can be set to read the code as one of three (3)
other J1939 versions if Version 4 is not being used. Most
engine ECU’s use Version 4, therefore in most cases
adjustment of this menu option will not be required.

Upon receiving an unrecognizable fault, change to a different
J1939 Version. If the fault SPN does not change when the
version is changed, the ECU generating the fault is using
Fault Conversion method 4. If the SPN number does not
change but is still unrecognizable, try changing to another
J1939 Version not yet used and continue to check the SPN
number.

SOFTWARE

VERSION

MURPHY: X.XX

GAGE DATA
REMOVE ALL GAGES
SOFTWARE VERSION

FAULT CONVERSION

J1939 VERSION 1

J1939 VERSION 2
J1939 VERSION 3

DCA-220SSJ/SSJU — DIAGNOSTIC DISPLAY