23.6.3 Auto Video Adjust

To adjust the video automatically:

Click Auto Video Adjust. The process takes a few seconds. If the process runs for
more than 3 times, there is an abnormal noise level. Check the video cable and
verify that no dynamic video application is running on the Target Server’s desktop.

Perform the procedure where necessary for each Target Server or new screen
resolution.

23.7 Power cycle

Where a Minicom Remote Power switch is connected to the Serial port of the IP
Control, you can power manage the Target servers as follows:

From the Toolbar, click

. The Power menu appears, see below.

Figure 18 Power menu

To send a power cycle command or to power down or up the currently accessed
Target server, select the appropriate option.

Note! Only the currently accessed Target server is affected, so to power manage
other Target servers you must access each one individually.

23.8 Keyboard key sequences

Click

. A list of defined keyboard sequences appears. When clicked, these

transmit directly to the Target Server, and will not affect the Client computer.

For example, select Ctrl-Alt-Del to send this three key sequence to the Target
Server to initiate its Shutdown/Login process.

To add a keyboard sequence:

Click Add/Remove. The Special Key Manager box appears see Figure 19.