Electrical wiring (milli-volt) – Monessen Hearth CSVF30SPV User Manual

Page 17

Advertising
background image

58D56002

17

PILO

T

HEA

T

THERMOST

AT

REMO

TE C

ONTROL

Figure 14 - Installing T-Stat Sensor and Control Knob

T-Stat

Sensor

Wiring

Harnesses

Screws

Knob

INSTALLING THERMOSTAT SENSOR
(OPTION SOLD SEPARATELY)

1. Lift up on ash lip and pivot down to open control

door.

2. Remove the face plate by removing the six (6)

screws holding the faceplate in place. This will

allow you to pull the faceplate away from the

unit about 3" to 4". See Figure 13.

3. Slip the t-stat sensor behind the faceplate. Attach

the t-stat sensor to the faceplate with 2 screws

provided. Make sure the thermo bulb wire is on

the bottom of the t-stat sensor. See Figure 14.

4. Attach wiring harnesses to back of t-stat sensor.

See Figure 14. Attach the other ends of the har

-

ness to either TP/TH and TH on control valve or

to existing wiring harness with two (2) 0.250"

male spade terminals for remote t-stat operation.

See Figure 12, page 16.

ELECTRICAL WIRING (MILLI-VOLT)

Figure 13 - Removing Face Plate from Unit

Screws

Face Plate

Thermo

Bulb

Screws

Control

Door

Ash

Lip

Advertising