Milli-volt, Thermostat control lighting instructions – Monessen Hearth CSVF30SPV User Manual

Page 23

Advertising
background image

58D56002

23

OFF

ON

OPERATING INSTRUCTIONS

Figure 23 - Pilot

TO TURN OFF GAS TO HEATER

1. Turn control knob clockwise

to OFF position to completely shut off the heater.

2. If applicable: Turn ON/OFF switch to OFF position and/or set thermostat (if present) to lowest setting.
3. If applicable: Turn off all electric power to the heater.

Figure 24 - Control Cover Plate for Milli-Volt

Hi/Lo Control

Ignitor/Pilot Control

On/Off Switch

(Located on Side

of Stove)

1. STOP! Read the safety information label.
2. Make sure the manual shutoff valve is fully open.
3. This gas log set is equipped with an ignition device (piezo) which automatically lights the pilot. If piezo

ignitor does not light the pilot, refer to instructions for Match Lighting Instructions, page 24.

4. Turn gas control knob clockwise

to the OFF position, set the thermostat to the lowest setting and

turn ON/OFF switch to OFF position.

5. Wait (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP!

Follow the instructions under “What To Do If You Smell Gas,” page 29.

6. From OFF position, turn the gas control knob counterclockwise

to IGN position. Push in

control knob for 5 seconds. NOTE: If you are running the heater for the first time, it may be

necessary to press in the control knob for 30 seconds or longer to allow air to bleed out
of the gas piping.

7. With the control knob pushed in, push in and release the piezo ignitor button to light the pilot.
8. Continue pushing the control knob in for a further 10 seconds to prevent the flame detector from shutting

off the gas while the probe is warming up. Release the control knob.

9. Turn gas control knob counterclockwise

to the ON position.

10. After the pilot has been lit for one minute, the burners can be turned on. Turn the ON/OFF switch to

ON position or adjust thermostat to desired setting. NOTE: To use the thermostat function (if

installed) the control knob must be set to “ON” and ON/OFF switch must be in the “OFF”
position.

11. If the gas logs will not operate, follow the instructions “To Turn Off Gas To Heater” below and call your

service technician or gas supplier.

MILLI-VOLT

AND

THERMOSTAT

CONTROL LIGHTING INSTRUCTIONS