2. 240 volt duplex receptacle (optional), 1. routine maintenance, 50 h – Miller Electric Big Blue 600D User Manual

Page 24

Advertising
background image

OM-481 Page 20

6-2.

240 Volt Duplex Receptacle (Optional)

Ref. ST-174 733 / ST-174 757

Y

If unit does not have GFCI recep-
tacles, use GFCI-protected exten-
sion cord.

1

240 V 15 A AC Duplex
Receptacle RC1

Receptacle supplies 60 Hz single-phase
power at weld/power speed. Maximum out-
put from this receptacle is 3 kVA/kW.

2

120 V 20 A AC Duplex Receptacle
GFCI2 (Section 6-1)

3

Circuit Breakers CB1 And CB2

CB1 and CB2 protect the 120 V and 240 V
receptacles from overload. If CB1 or CB2
opens, the 240 V receptacle and one half of
the 120 V receptacle does not work. 120
volts may still be present at the 240 volt re-
ceptacle. Press button to reset breaker.

.

If a circuit breaker continues to open,
contact a Factory Authorized Service
Agent.

4

Total Generator Power Output

Combined output of all receptacles limited
to 3 kVA/kW output of the generator.

EXAMPLE: If 10 A is drawn from the 240 V
receptacle, only 5 A is available at the 120
V receptacle:

(240 V x 10 A) + (120 V x 5 A) = 3.0 kVA/kW

1

3

4

2

SECTION 7 – MAINTENANCE & TROUBLESHOOTING

7-1.

Routine Maintenance

Follow the storage procedure in the engine owner’s manual if the unit will not be used for an
extended period.

Note

Recycle engine

fluids.

Y

Stop engine before maintaining.

.

See also Engine Manual and Mainte-
nance Label. Service engine more often
if used in severe conditions.

*

To be done by Factory Authorized
Service Agent.

8 h

Check Fluid
Levels. See
Section 4-4.

Wipe

Up

Spills.

OIL
Full

Drain Water

From Fuel

System.

FUEL

WATER

50 h

Clean Air Filter.

See Section 7-3.

Clean And

Tighten

Weld

Terminals.