Wr / wc series woodburning fireplace, Installing line for gas logs – Monessen Hearth WR400 User Manual

Page 18

Advertising
background image

18

WR / WC Series Woodburning Fireplace

20014528

Installing Line for gas Logs

MHSC fireplaces are designed to accept a 1/2" (13 mm)
gas line for installation of an approved gas appliance.
(MHSC manufactures a wide variety of gas logs for use
in MHSC fireplaces.)
Be sure to have the appliance installed in accordance
with building codes.
Gas connection may enter from either left or right side
of the fireplace.
Locate appropriate gas line in the outer casing of fire-
place and remove insulation from gas line tube. (Fig.
26)
From inside the fireplace, locate the knockout on the
firebrick -- be sure you are on the appropriate or "gas
line" side of the fireplace. Using a flat bladed screw-
driver or small chisel and hammer, carefully tap around
the knockout until it loosens and falls out.
Install 1/2" (13 mm) certified gas pipe through opening.
After gas pipe installation is complete, use insulation
that was removed from gas line tube to repack space
around the pipe. Material should be inserted from
outside of the fireplace and packed tightly to totally seal
between the pipe and tube.
NOTe: gas pipe should not come in contact with
any wood structures until it has reached a point at
least one (1) inch away from fireplace side.
NOTe:
When installing an ANSI Z21.11.2 ventless ap-
pliance the finishing material used for the mantel must
be rated at 250°F or greater.
BTU input of a gas appliance installed in fireplace
should be rated less than 100,000 BTU/Hr.
Gas pipe installation is intended for connection to a
decorative gas appliance only when (1.) incorporating
an automatic shutoff device and (2.) complying with the
Standard for Decorative Gas Appliances for Installa-
tion in Vented Fireplaces (ANSI Z21.60) or CSA draft
requirements for Gas-Fired Log Lighters for Woodburn-
ing Fireplaces (Draft No. 4, August 1993).
Decorative gas appliance should be installed in accor-
dance with the National Fuel Gas Code, ANSI Z223.1/
NFPA 54 (latest edition).

Only unvented gas logsets which have been found to com-
ply with the Standard for Unvented Room Heaters, ANSI
Z21.11.2, are to be installed in this fireplace.

CAUTION: WHeN USINg DeCORATIVe
gAS APPLIANCe, FLUe DAMPeR MUST
be SeT IN FULLY OPeN POSITION. IF YOU
HAVe gLASS DOORS ON THe FIRePLACe,
THeY MUST ALSO be FULLY OPeNeD.

WARNINg: DO NOT OPeRATe AN
UNVeNTeD gAS LOg SeT IN THIS FIRe-
PLACe WITH THe CHIMNeY ReMOVeD.

WARNINg: WHeN INSTALLINg AN
UNVeNTeD gAS LOg SeT, THe MHSC
MODeL CAbL OR CAbR 4" ADJUSTAbLe
HOOD MUST be USeD.

If installing an unvented gas log set, refer to statement below:

Hole in Outer Casing

FP560

Fig. 26 Gas line access.

1"

Min.

FP560

BR/BC

11/10/97

1/2"

Gas Line

Tube

Ceramic

Knockout

Supply

Line

Repack Insula-

tion

Ceramic

Knockout

(Both sides)

Hole in

Casing

Fireplace Top View