background image

Protected applications

Best choices

Backup time

100-line PABX (300 VA)

Pulsar EXtreme 700C + 3 Pulsar EXB 700C

2 hours

1 UNIX server (650 VA)

Pulsar EXtreme 700C

7 minutes

Pulsar EXtreme 1000C + Pulsar EXB 1000C

50 minutes

6 Internet servers/1U rack (1500 VA)

Pulsar EXtreme 1500C

6 minutes

Pulsar EXtreme 1500C + Pulsar EXB 1500C

25 minutes

Pulsar EXtreme 1500C + 2 Pulsar EXB 1500C

40 minutes

High performance LAN Switch (1500 VA)

Pulsar EXtreme 1500C + 3 Pulsar EXB 1500C

80 minutes

High availability

Pulsar EXtreme C UPSs guarantee a high level of

availability, equal to 99.999% or higher.

A complete range

Which model to choose ?

High performance and reliability

Pulsar EXtreme C provides power protection and extends battery life to increase

system reliability.

Pulsar EXtreme C UPSs have been

designed to meet the needs of modern

equipment, including network, intranet

and internet servers, internetworking

devices, computer and telecom (PBX)

centres, medical equipment and sensitive

industrial processes.

Pulsar EXtreme C is available in both

tower and rack versions with power

ratings from 700 to 1500 VA.

On-line double conversion

technology

Pulsar EXtreme C UPSs use double

conversion (on-line) technology, the only

way to overcome all power problems.

The battery is used only as a backup source.

Whatever the disturbances on the distribution system, the
waveform is regenerated via the AC to DC then DC to AC
conversion process.

High-performance battery

charger

The Pulsar EXtreme battery charger:

• reduces battery recharge time (80%

backup time recovered in two hours);

• increases the service life of the battery

by taking into account manufacturer

parameters and battery aging;

• protects the battery against damage

caused by deep discharge;

• avoids disturbances on the distribution

system by correcting the power factor;

• avoids propagating faults on the

distribution system (backfeed

protection).

Certified compliance with

CE and UL standards

Cold start on battery power

This function ensures trouble-free start-up

of your applications even during a utility

power outage.

High-availability pack

A Pulsar STS source transfer switch

combined with two Pulsar EXtreme C UPSs

provides effective power redundancy.

Battery

Filter

Filter

Automatic bypass

Bypass mode

On-line mode

Pulsar EXtreme Rack
"preferred" source

Pulsar EXtreme Rack
"alternate" source

Automatic bypass

In the event of an overload or UPS fault,

Pulsar EXtreme C automatically transfers

the load to utility AC power.

Wide input-voltage range

Pulsar EXtreme C UPSs have a very wide

input-voltage range from 120 to 276 V,

optimized to improve compatibility with

engine generator sets and reduce the

number of transfers to battery power.

The batteries are used only for the most

serious incidents, maximizing available

backup time and extending battery life.