STARLINE 7

Figure 7 illustrates the 2X redundant return configuration board. Jumpers

J

5

and

J

6

are shown

in the normal default position. Jumper

J

6

enables/disables signal flow to output connector

J

8

(Tx2). Jumper

J

5

terminates input connector

J

3

(

IN2

) when only a single RF input is used.

Figure 7
2X redundant return configuration board

J9

T3

Q1

C15

R1

J4

J1

J2

C9

T1

J5

J6

C10

TERM

TERM

J7

J8

C11
R7

T2

C12

J3

IN1

IN2

TX2

TX1

R2

R1

1

C5

C4

R13

R16

R10

R4

C7

C8

C13

C6

R3

R8

R5

R1

2

C18

R1

4

R15

L1

C16

C1

9

C14

C17

R6

C2

C1

C3

SM

J5

J6

Figure 8 illustrates the signal flow through the 2X redundant return board:

Figure 8
2X redundant return board- signal flow

Loss = 0.9 dB

J6

-0.5 dB

-3.5 dB

+7.5 dB

-3.5 dB

TX2

TX1 SM

J5

IN2

IN1

To set up the split return option:

1

Confirm that the SG4-DRT-2X is installed in lid optics slots 3 and 4, or 5 and 6.

2

Confirm that a 2X redundant return board is installed in lid return configuration board
locations 2 and 3 as illustrated in Figure 5.

3

Position

J

6

in the right-most position to terminate the output to transmitter two.

4

Connect an RF cable from the 2X redundant return board, in lid return configuration board
location 2, to CH B of the SG4-DRT-2X .

5

Connect an RF cable from the 2X redundant return board, in lid return configuration board
location 3, to CH A of the SG4-DRT-2X.

The RF cables should be approximately eight inches long and have red boots on the
connector signifying the return path.

6

If necessary, connect the appropriate return RF cables from the SG4-RF modules to each 2X
redundant board.

SG4-DRT-2X Installation Sheet