For technical questions, please call 1-800-444-3353.

SKU 94822

Operating Instructions

1. Before loading and while stationary, lock the back

Casters (19) to prevent the Lift Table from moving.

2. The Table (1) is raised by pumping the Lifting Pedal

(27) with your foot until the desired height is achieved.

3. Once desired height is reached, swing down the

Safety Bars (7) on either side of the Lift Frame. This

will prevent any kind of uncontrolled Table drop.

4. To lower the Table, Squeeze the Release

Handle (22) at the top of the main Handle.

Note: Be sure to lift Safety Bars up, allowing the

Table to be completely lowered (if needed).

maintenance

1. Lubricate hydraulic connections monthly

with a good quality grease.

2. Check for the free movement and wear

of the wheels. Replace if needed.

3. Check the Caster brakes regularly. They

should lock firmly and release completely.

4. If you encounter difficulty using the Release

Handle to lower the Table, the Control

Cable (49) may need adjusting.

WARNING! Make sure the Release Handle is pressed

only halfway down during adjustment. This will allow

the Table to lower slowly for safety purposes.
a. With assistance, tip over Lift Table.

b.

Hex Bolt (16)

Cable Bolt (50)

Control Cable (49)

Figure 5

Loosen the Cable Bolt (50) and Cable Nut

(51) and tug the Control Cable until it is tight.

WARNING! Do not pull too tight; you want to

leave a small amount of give. See Figure 5.

c. Re‑fasten the Nut and Bolt. Then test the

Release Handle, making sure the Release

Handle is pressed halfway down.

5. Check for oil leakage from the hydraulic cylinder.

The hydraulic cylinder is not user serviceable.

WARNING! Any service or repairs to the Hydraulic

Lift Table should be performed by a qualified

service technician. Improper repairs or service

could result in equipment failure or personal injury.

Bleeding Instructions

If the Lift Table is not performing properly, it may

be due to air in the hydraulic system. Follow

these steps to bleed air from the system.

1. Raise the Table to it’s highest position.
2. Swing down the two Safety Bars so that they both

rest on the top platform of the Base Assembly.

3. Remove the rubber Oil Plug (J04). You can carefully

remove it with a large flat head screwdriver.

4. After the Oil Plug is removed, swing the two

Safety Bars back against their stops.

5. Squeeze the Release Handle to lower the Table. This

should purge the air out of the hydraulic system.

6. Raise the Table to it’s highest position and swing both

the Safety Bars down onto the Base Assembly (17).

7. Top off hydraulic fluid into the oil hole where the Oil Plug

goes until it is full.

Note: make sure you use new oil.

8. Replace the Oil Plug by firmly

pressing it in while twisting it.