4. battery charging procedure – Miller Electric OM-4409 User Manual
Page 45
OM-4409 Page 41
8-4. Battery Charging Procedure
Stop Engine.
Connect Cables (Observe
Correct Polarity).
Set Output Selector Switch To
Voltage Of Battery Being
Charged (12 Or 24 Volt).
NOTICE − Do not switch under load.
+
−
Start Engine.
Set Process/Contactor Switch To
Any Remote On/Off Switch Required
Position.
In Example:
Battery Voltage = 12 Volts
Battery CCA Rating = 500
Charge Current = 100 A (See Section 8-2)
Ampere Range Setting = 55 to 125 A
V/A Control Setting = Any Position
.
This battery charging procedure uses
the front panel controls to turn charging
output on and off.
Charge 10 minutes. Check
Battery Voltage. Continue
Charging If Necessary.
Set Process/Contactor Switch
To Any Weld Terminals Always On
Position To Begin Charging.
.
To control battery charging output using a
remote device connected to the Remote
14 receptacle, keep Process/Contactor
switch in Remote On/Off Switch Required
position and use remote device to turn
charging output on and off.
Determine Charge Current From
Battery CCA Rating And Chart
Set Ampere Range Switch To Lowest
Range That Exceeds Charge Current.
NOTICE − Do not switch under load.