13. installing non-pd (old style) wire guides – Miller Electric SS-75S12 User Manual

Page 20

Advertising
background image

OM-230 298 Page 16

4-13. Installing Non-PD (Old Style) Wire Guides

Ref. 804 732-A

Installing wire guides with non- PD (old-

style) drive rolls

.

Non-PD (old-style) wire guides and
drive rolls should be used with 5/64 in

(2.0 mm) and larger diameter wire.

1

PD Inlet Guide

2

Intermediate Guide

3

Guide Holder

4

Exit Guide

5

Set Screw

6

Pressure Door Assembly

Open pressure door assembly.
Lift up drive roll swing arms.
Install PD inlet guide.

.

Do not tighten set screw to secure inlet
guide.

.

Set screw may be used to secure PD
inlet guide replacements such as wire

straighteners or conduit adapters.

Remove screw securing intermediate guide

holder. (Guide holder is located between

the lower front and rear drive roll carriers.)

Rotate guide holder 180 degrees and rein-

stall.
Install intermediate guide into guide holder

and tighten set screw.
Loosen set screw, insert exit guide into

block near brass power pin gun connection

and secure with set screw.

.

When using smaller diameter inlet
guide (219108) with non-PD (old style)

drive rolls, a 1/4 in (6 mm) gap will be

present between the guide and drive

roll.

Tools Needed:

1/16, 1/8, 5/32 in

2

1

3

4

5

6

Advertising