4. troubleshooting – Miller Electric SS-75S12 User Manual

Page 29

Advertising
background image

OM-230 298 Page 25

6-4. Troubleshooting

Y Disconnect power before troubleshooting

Trouble

Remedy

Wire feeds, shielding gas flows, but

electrode wire is not energized.

Check interconnecting cord connections. If secure, check cord for continuity and repair or replace

(see Sections 4-5 and 4-6).

Wire feeder is on, display does not

light up, motor does not run, gas valve

and welding power source contactor do

not pull in.

Check and reset circuit breaker at welding power source.

Electrode wire feeding stops or feeds

erratically during welding

Check gun trigger connection. See gun Owner’s Manual.

erratically during welding.

Check gun trigger. See gun Owner’s Manual.

Readjust hub tension and drive roll pressure (see Section 4-15).

Change to correct size drive roll (see 4-11).

Clean or replace dirty or worn drive roll.

Incorrect size or worn wire guides.

Replace contact tip or liner. See gun Owner’s Manual.

Remove weld spatter or foreign matter from around nozzle opening.

Have Factory Authorized Service Agency check drive motor or motor control board PC1.

Motor runs slowly.

Check for correct input voltage.

Wire feeder power is on, displays light

up, unit jogs and purges but will not

trigger.

Check welding gun trigger leads for continuity, and repair leads or replace gun.

When triggered wire feeds but no gas,

no contactor.

If the welding arc does not establish in 3 seconds after the gun trigger is activated the unit will feed

wire, but turns off contactor and gas valve. If the gun trigger is still activated after two minutes, the

wire will stop feeding.

Advertising
This manual is related to the following products: