CHECKPOINTS BEFORE USE

1. Check that all parts of the respirator are

complete and undamaged. See Use and

Care section for Inspections

Procedures.

2. Check that the filter cartridge/canister

approval matches the contaminant in

the environment.

INSTALLING/REPLACING THE

CARTRIDGE/CANISTER

Know the contaminant(s) in the environ-

ment before entering. Always check that

the filter cartridge/canister is appropriate

for use in the environment. A filter car-

tridge/canister which is not designed for

the contaminant present may not provide

protection. Failure to follow this warning

can result in serious personal injury or

death.
After checking cartridge/canister for

approval in the environment:

1. Verify shelf life expiration date on car-

ton, bag, and cartridge/canister label

has not been exceeded.

Do not use an expired cartridge/canister.

Failure to follow this warning can result

in serious personal injury or death.

Do not use the cartridge/canister if the

foil bag or carton is opened, damaged, or

missing. The cartridge/canister must be

in its original packaging for uses in a

contaminate environment. Do not reuse

the cartridge/canister. Failure to follow

this warning can result in serious person-

al injury or death.

2. Remove cartridge/canister from its

packaging.

3. Inspect the cartridge/canister to be sure

that its service life is suitable, and that it

is not damaged.

4. Thread the filter cartridge/canister into

the facepiece port and hand-tighten.

Use the cartridge/canister immediately upon

opening the bag. Discard cartridge/canister

after each use.
Replace the cartridge/canister after each

use. Follow the established cartridge/canis-

ter change-out schedules to ensure that

cartridge/canisters are replaced before

breakthrough occurs. When used at defined

occupational exposure limits, the rated ser-

vice time cannot be exceeded.

For CBRN Applications Only:

DO NOT use this respirator beyond eight (8)

hours after initial use in an atmosphere con-

taining CBRN agents or beyond two (2)

hours after initial use in an atmosphere con-

taining CBRN agents in liquid or mist form;

otherwise, agent permeation may occur.

Do not replace cartridge/canister in a

contaminated area. Failure to follow this

warning can cause inhalation of contami-

nated air, resulting in serious respiratory

injury or death.

When the mask is adjusted properly, the

wearer should not taste or smell the conta-

minant, or experience eye, nose, or throat

irritation. The wearer's inhalation resistance

should be as experienced during training.

If the respirator does not perform as

specified, it must not be used until it has

been checked by authorized personnel.

Failure to follow this warning can result

in serious personal injury or death.

Return to fresh air immediately if you

experience unusual sensations (nausea,

dizziness, eye irritation, unusual odor or

taste, excessive fatigue, or difficulty

breathing). Failure to follow this warning

can result in serious personal injury or

death.

11

TAL 403 (L) Rev. 4 - 430351

PREPARING THE RESPIRATOR FOR USE

WARNING

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!

WARNING

!