Inspection – Millennium Enterprises GME-P100 User Manual

Page 22

Advertising
background image

17. Reinstall the rubber

cover. Be sure that the

cover lip surrounds

the valve completely

and that the tab is

inserted through the

cover.

18. Check the drink tube for cuts, abra-

sions, or other signs of damage. Grasp

the knurled surface and pull the tube

out of the cover to check it for signs of

damage. Be sure the tube is reinstalled

in its port completely.

19. Reinstall the voice-

mitter gasket in the

side port. Be sure that

it is flat.

20. Place the voice-mitter into the port.

Note:

The voice-mitter's crimped side faces

out (up).
21. Thread the retaining ring into the port

and tighten using the spanner wrench.

22. Place the deflector (with the inhalation

valve in place on the post) into the face-

piece.

23. Line up the deflector

so that it is between

the guide tabs molded

into the facepiece.

24. While holding the deflector in place,

press the spider gasket on to the post

from outside the facepiece.

25. Insert the gasket

groove into the port

so that the groove

captures the lip of the

port completely. Run

your finger around the

gasket to be sure the

gasket lays flat.

26. Thread the cartridge/canister into the

port. (see Preparing the Respirator for

Use section)

27. If any part is damaged or deteriorated, it

must be replaced. Store only undam-

aged respirators for further use. When

not in use, store the respirator in cool,

dry, and clean ambient air. Keep new fil-

ters in their packing.

TAL 403 (L) Rev. 4 - 430351

22

INSPECTION

Guide Tabs

Advertising