Metabo Welding Transformers and Rectifiers SB 160 C User Manual

Page 8

Advertising
background image

Arc Length

The arc length "a", that is the distance between the stick electrode and the work, should be:

with stick electrodes of coating type R, RR, A, C

=

1.0xd,

with stick electrodes of coating type B

=

0.5xd,

Too long an arc reduces the penetration, increases the arc blow effect and, particularly with basic coated stick
electrodes, causes a porous weld seam.

3.1.6 Welding Positions According to DIN 1921

3.1.5 Arc Starting and Arc Burning

Arc Strike

Always start the arc in the welding groove.
When the arc is stable weld over the arc strike and melt for good fusion, otherwise there is a risk of cracking.

d

a

wrong

correct

arc strike

arc strike

open-circuit voltage Short-circuit voltage

3 to 5 V

working voltage
20 to 30 V

Arc starting
sequence

q

q = horizontal-vertical position

f

s

ü = overhead position

ü

w = gravity position

w

w

h

h = horizontal position

s = vertical-up position
f = vertical-down position

18

Advertising
This manual is related to the following products: