17

Read Data Format

In read mode (R/W = 1), the MAX9777 writes the con-
tents of the selected register to the bus. The direction of
the data flow reverses following the address acknowl-
edge by the MAX9777. The master device reads the
contents of all registers, including the read-only status
register.

Table

6 shows the status register format.

Interrupt Output (

INT)

The MAX9777 includes an interrupt output (INT) that
can indicate to a master device that an event has
occurred. INT is triggered when the state of HPS
changes. During normal operation, INT idles high. If a
headphone is inserted/removed from the jack and that
action is detected by HPS, INT pulls the line low. INT
remains low until a read data operation is executed.

I

2

C Compatibility

The MAX9777 is compatible with existing I

2

C systems.

SCL and SDA are high-impedance inputs; SDA has an
open drain that pulls the data line low during the ninth
clock pulse. The communication protocol supports the
standard I

2

C 8-bit communications. The general call

address is ignored. The MAX9777 slave addresses are
compatible with the 7-bit I

2

C addressing protocol only.

*Default

REGISTER ADDRESS

0000 0011

BIT

NAME

VALUE

DESCRIPTION

7

X

Don’t Care

6

X

Don’t Care

5

X

Don’t Care

0*

Speaker mode selected

4

SPKR/HP

1

Headphone mode
selected

0*

Gain-setting A selected

3

GAINA/B

1

Gain-setting B selected

0*

Automatic headphone
detection enabled

2

HPS_D

1

Automatic headphone
detection disabled
(HPS ignored)

0*

Input 1 selected

1

IN1/IN2

1

Input 2 selected

0

X

Don’t Care

Table 5. MAX9777 Control Register Format

REGISTER ADDRESS

0000 0000

BIT

NAME

VALUE

DESCRIPTION

0

Device temperature below thermal limit

7

THRM

1

Device temperature exceeding thermal limit

0

OUTR- current below current limit

6

AMPR-

1

OUTR- current exceeding current limit

0

OUTR+ current below current limit

5

AMPR+

1

OUTR+ current exceeding current limit

0

OUTL- current below current limit

4

AMPL-

1

OUTL- current exceeding current limit

0

OUTL+ current below current limit

3

AMPL+

1

OUTL+ current exceeding current limit

0

Device in speaker mode

2

HPSTS

1

Device in headphone mode

1

X

Don’t Care

0

X

Don’t Care

Table 6. MAX9777 Status Register Format

Advertising