1. Remove upper shell (see

page 10).

2. Remove filter end cover

screws using 5/16" nut-
driver.

3. Remove filter end cover.
4. Replace air output and lint

filters.

5. Wash or replace air intake

filter (see Preventative
Maintenance Schedule,
page 8).

6. Replace filter end cover.
7. Replace fan guard and

upper shell.

IMPORTANT:

Do not oil filters

Air Intake Filter

Filter End
Cover

Lint Filter

Air Output
Filter

Figure 10 - Air Output, Air Intake, and Lint Filters

Fan Guard

Figure 12 - Adjusting Pump Pressure

Figure 11 - Pressure Gauge Plug Removal

Pressure
Gauge

Pressure
Gauge Plug

Relief Valve
Location

Pump Pressure
Adjustment

1. Remove pressure gauge

plug from filter end cover.

2. Install accessory pressure

gauge (part number
HA1180).

3. Start heater (see Operation,

page 7). Allow motor to
reach full speed.

4. Adjust pressure. Turn relief

valve to right to increase
pressure. Turn relief valve
to left to decrease pressure.
See specifications at right
for correct pressure for
each model.

5. Remove pressure gauge.

Replace pressure gauge
plug in filter end cover.

PUMP

MODEL

PRESSURE

150,000 Btu/Hr

4.8 PSI