Specifications – Master Lock BR150CE User Manual

Page 15

Advertising
background image

15

102384

Fan

IMPORTANT:

Remove fan

from motor shaft before
removing motor from heater.
The weight of the motor
resting on the fan could
damage the fan pitch.

1. Remove upper shell (see

page 10).

2. Use 1/8" allen wrench to

loosen setscrew which
holds fan to motor shaft.

3. Slip fan off motor shaft.
4. Clean fan using a soft cloth

moistened with kerosene or
solvent.

5. Dry fan thoroughly.
6. Replace fan on motor

shaft. Place fan hub flush
with end of motor shaft
(see Figure 19).

7. Place setscrew on flat of

shaft. Tighten setscrew
firmly (40-50 inch-pounds/
4.5-5.6 n-m).

8. Replace fan guard and

upper shell.

Motor
Shaft

Setscrew

Figure 18 - Fan, Motor Shaft, and Setscrew Location

Motor
Shaft

Fan

Setscrew

Figure 19 - Fan Cross Section

Output Rating (Btu/Hr)

150,000

Fuel

Use Only Kerosene or No. 1 Fuel Oil

Fuel Tank Capacity

(U.S. Gal./Liters)

13.5/51.1

Fuel Consumption

(Gal. Per Hr./Liters Per Hr.)

1.1/4.1

Electric Requirements

220 V/50 Hz

Amperage (Normal Run)

1.2

Hot Air Output (CFM/CMM)

500/14.2

RPM

2850

SPECIFICATIONS