Appendix C - POST Test Error Codes

POST Test Error Code Sample

NOTE:

This example applies to 8, 16, 32, and 48 port LX units. The 16, 32, and 48 port
LX units use only the first eight LEDs when generating error codes.

The following sample illustrates the Port Status LED sequence for Error 2030 (Reading Invalid Value
from PLD System Fail Status Register) on the LX-4008. In this example:

1. A POST test failure occurs on an 8-port unit. All LEDs flash eight times, very quickly, then the error code

is displayed.

2. You record that LED 3 turns on. Again, all LEDs flash eight times very quickly, then the rest of the error

code is displayed.

3. You record that LEDs 3 and 4 turn on. Figure 22 explains how to interpret the sample error code.

NOTE:

In hexadecimal, 0 indicates the LED is OFF. 1 indicates the LED is ON.

Each group of four LEDs is converted to a hexadecimal value as follows:

0 = 0000

1 = 0001

2 = 0010

3 = 0011

4 = 0100

5 = 0101

6 = 0110

7 = 0111

8 = 1000

9 = 1001

CD1400 Invalid Data Received for Quadart 6

4460

CD1400 Invalid Data Received for Quadart 7

4470

CD1400 Invalid Data Received for Quadart 8

4480

CD1400 Invalid Data Received for Quadart 9

4490

CD1400 Invalid Data Received for Quadart A0

44A0

CD1400 Invalid Data Received for Quadart B0

44B0

CD1400 Invalid Data Received for Quadart C0

44C0

Memory Error at (printing address)

5010

Memory Data Bus Failed

5020

Memory Address Bus Failed High

5030

Memory Address Bus Failed Low

5040

Flash Checksum Error

5055