10. remote 14 receptacle rc8, 11. remote 14 receptacle rc8 information – Miller Electric Delta-Fab User Manual

Page 18

Advertising
background image

OM-2241 Page 14

3-10. Remote 14 Receptacle RC8

Ref. 800 166-D

Y Turn off power before con-

necting to receptacle.

1

Remote 14 Receptacle RC8

Connect feeder to RC8.

A

J

B

K

I

C L N

H

D M

G

E

F

1

3-11. Remote 14 Receptacle RC8 Information

Socket

Information

24 VOLTS AC

A

24 volts ac. Protected by supplementary protector CB2.

24 VOLTS AC

B

Contact closure to A completes 24 volts ac contactor control circuit.

C

Command reference; 0 to +10 volts dc.

REMOTE OUTPUT CONTROL

D

Remote control circuit common.

E

0 to +10 volts dc input command signal from remote control.

F

Current feedback; 1 volt per 100 amperes.

H

Voltage feedback; 1 volt per 10 arc volts.

115 VOLTS AC

I

115 volts, 15 amperes, 60 Hz ac. Protected by supplementary protector CB1.

115 VOLTS AC

J

Contact closure to I completes 115 volts ac contactor control circuit.

GND

K

G

Chassis common.
Circuit common for 24 and 115 volts ac circuits.

REMOTE POWER ON/OFF

To remote On/Off switch

REMOTE POWER ON/OFF

*

To remote On/Off switch.

REMOTE VOLTAGE SENSING

*

Voltage sensing signal from Negative (−) weld output terminal.

REMOTE VOLTAGE SENSING

*

Voltage sensing signal from Positive (+) weld output terminal.

* Not Used

Advertising