5-4. Troubleshooting Table

Trouble

Remedy

No weld output; unit completely

inoperative.

Place line disconnect switch in On position (see Section 3-14).

Check fuse F1, and replace if necessary (see Section 5-2).

Check and replace line fuse(s), if necessary, or reset circuit breaker (see Section 3-14).

Check for proper input power connections (see Section 3-14).

Check for proper jumper link position (see Section 3-14).

No weld output; Power switch pilot light

on; fan on.

Check, repair, or replace feeder (see wire feeder Owner’s Manual).

Unit overheated. Allow unit to cool with fan On (see Section 3-2).

Have Factory Authorized Service Agent check control board PC1.

Unit provides only maximum or mini-

mum weld output.

Have Factory Authorized Service Agent check control board PC1.

Erratic or improper weld output.

Use proper size and type of weld cable (see Section 3-8).

Clean and tighten all weld connections.

Check wire feeder installation according to Owner’s Manual.

Have Factory Authorized Service Agent check control board PC1 and/or SCR in main rectifier.

No 115 volts ac output at duplex

receptacle or Remote 14 receptacle.

Reset supplementary protector CB1 (see Section 3-7).

No 24 volts ac output at Remote 14 re-

ceptacle.

Reset supplementary protector CB2 (see Section 3-7).

Fan not operating.

Check for and remove anything blocking fan movement.

Have Factory Authorized Service Agent check fan motor.