QP3TY — INITIAL START-UP (ENGINE)

Stopping The Engine

Normal Shutdown

1. Move the engine speed lever to the low speed and run the

engine for about three minutes with no load.

2. After the engine cools, move the engine speed lever to the

STOP position (Figure 11).

3. Close the fuel cock (Figure 12).

4. Slowly pull the starter grip (Figure 9) until strong resistance

is felt and leave it in this position. This prevents rust from
forming while the engine is not in use.

When stopping the engine, reduce the load slowly. Do
not stop engine suddenly since it may cause the
temperature to rise abnormally.

CAUTI

CAUTI

CAUTI

CAUTI

CAUTION

Emergency Shutdown

1. To stop engine immediately, quickly place the engine speed

lever to the STOP position.

Figure 11. Engine Speed Lever (STOP Position)