Appendix b, M1d specifications – Meyer Sound M1D User Manual

Page 27

Advertising
background image

21

APPENDIX B

APPENDIX B

M1D SPECIFICATIONS

ACOUSTICAL
Note:
The low-frequency power response of the system will increase according to the length of the array.
Operating frequency range

60 Hz - 18 kHz
Note: Recommended maximum operating frequency range. Response depends upon

loading conditions and room acoustics.

Frequency response

75 Hz - 15 kHz ±4 dB

Note: Free field, measured with 1/3 octave frequency resolution at 4 meters.

Phase response

800 Hz - 12 kHz ±45°

Maximum peak SPL

125 dB at 1 m
Note: Measured with music at 1 meter.

Dynamic range

>110 dB

Horizontal coverage

100°

Vertical coverage

Varies, depending on array length and configuration; for a single loudspeaker, 10° minimum.

Acoustical crossover

1900 Hz
Note: At these frequencies, the transducers produce equal sound pressure levels.

TRANSDUCERS
Low frequency

Two 5" cone drivers

Nominal impedance: 8 Ω

Voice coil size: 1"

Power-handling capability: 200 W (AES)
Note: Power handling is measured under AES standard conditions: transducer driven

continuously for two hours with band limited noise signal having a 6 dB peak-average ratio.

Note: To eliminate interference at short wavelengths, the two 5" drivers work in combination at low frequencies (60 Hz

– 1000 Hz). At mid frequencies (1000 Hz – 1900 Hz) only one cone driver is fed from the crossover to maintain optimal

polar and frequency response characteristics.
High frequency

Three 0.75" metal dome tweeters with neodymium magnets

Nominal impedance: 8 Ω

Voice coil size: 20 mm

Power-handling capability: 15 W (AES)
Note: Power handling is measured under AES standard conditions: transducer driven

continuously for two hours with band limited noise signal having a 6 dB peak-average ratio.

Note: The three drivers are coupled to a constant-directivity horn.

AUDIO INPUT
Type

Differential, electronically balanced

Max. common mode range

±15 V DC, clamped to earth for voltage transient protection

Connectors

Female XLR input with male XLR loop output

Input impedance

10 kΩ differential between pins 2 and 3

Wiring

Pin 1: Chassis/earth through 220 kΩ, 1000 pF, 15 V clamp network to provide virtual

ground lift at audio frequencies

Pin 2: Signal +

Pin 3: Signal -

Case: Earth ground and chassis

DC Blocking

Differential DC blocking up to max common mode voltage

CMRR

>50 dB, typically 80 dB (50 Hz – 500 Hz)

RF filter

Common mode: 425 kHz; Differential mode: 142 kHz

TIM filter

<80 kHz, integral to signal processing

Advertising