Caution, Safety working – Matsushita CF-19FHGAX User Manual

Page 33

Advertising
background image

 Assembly of Inverter PCB (Applicable Model : Touch Screen Model)

Inverter

 Ass'y

Inverter

 Ass'y

0

   4mm

0

   0.5mm

A

0

   3mm

Connector

PWB

FPC

12

Confirm

 the direction of the Inverter board when attaching.

 

30

    35mm

Inverter

 Ass'y

LCD

 Back Dumper

LCD

 Ass'y

Inverter

 Mil Sheet

The

 gap side is front.

0

   1mm

Attach

 coming over the end of steel plate by 1 to 2 mm.

Avoid

 any stress on the Tab part of the 

LCD

 Module because the line comes off.

Wrap

 of Antenna Cable 

Cushion

 E

Conductive

 Tape

Wrap

 over the Antenna Cable 

Cushion

 and the Cable.

6

    2mm from the 

branch

 point

Connect

Fix

 the two Cables 

and

 connector.

Insulation

 Parts

Insulation

 Parts

Insulation

 Parts

Insulation

 Parts

Note

 for attaching Conductive Tape

Conductive

 Tape

Tape

Connect

 the Cable to the 

left

 and right Connectors.

LCD

 Cable TS

Attach

 the Inverter Ass'y in the 

middle

 of right and left.

Attach

 the surplus of the right and left sides on the 

Back

 Dumper as shown below and overlap on the 

CCFL

 Cable. Attach the Pet Sheet over the Core.

LCD

 Side Cushion E

LCD

 Side Cushion E

LCD

 Side Cushion F

Insert

 it between the ribs. 

(Fit

 to the Cabinet.)

Insert

 it between the ribs. 

(Fit

 to the Cabinet.)

Insert

 it between the ribs. 

(Fit

 to the Cabinet.)

Cushion

 High 

Voltage

 Label

TS

 PWB

Connect

Attach

 it to the Connector and FPC.

Avoid

 getting under the Sheet.

Sield

 Sheet

Wind

 round the LCD Cable 

a

 few times and attach it.

Avoid

 any stress on the Cable 

when

 connecting it.

Hold

 the Connector part when 

connecting/disconnecting.

Sub

 material: Pet Tape 1

Ensure

 the edge of the 

conductive

 fabric is not 

frayed.

Details

 of "A"

1

   2

mm

Avoid

 any stress on the Cable when 

connecting

 the CCFL Cable.  

Hold

 the Connector part when 

connecting/disconnecting.

Inverter

 Ass'y

S2

Details

 of cable

Avoid

 running over the rib

CAUTION

S1:Insulation

  S2:Pinching Cables  S3:Sharp Edge

S4:Part

 No. Check  S5:Others

Safety

 Working

S5

Advertising