POWER CORD AND PLUG
REQUIREMENTS

120V, 30-amp twist-lock receptacle

• NEMA L5-30P plug

• Three-wire, 30-amp cord

120/240V, 20 or 30-amp twist-lock
receptacle

• NEMA L14-20P (20-amp) or L14-30P

(30-amp) plug

• Four-wire, 20-amp or 30-amp cord

120/240V, 50-amp receptacle

• NEMA L14-50P

• Four-wire, 50-amp cord

w

G

Y

X

Ground

X

(Hot)

W

(Neutral)

Y

(Hot)

Ground
(Green)

L14-20P
Plug

120V

120V

Neutral

120/240 Volt

20 Amp

w

G

Y

X

w

G

Y

X

120V

120V

Neutral

Ground

Ground

X

(Hot)

W

(Neutral)

Y

(Hot)

Ground
(Green)

L14-30P
Plug

L14-20P
Plug

120V

120V

Neutral

w

G

Y

X

Ground L14-50P

Plug

120/240 Volt

20 and 30

Amp

120V

120V

Neutral

Figure 16 - Cord and Plug Configurations

Continued

Model MGH10000 also has a 120/240V,
50-amp receptacle (see Figure 15).

Model HWI3000 has only the 120V, 20-
amp duplex receptacle.

Models MGH3000 and MGH3000PR have
only the 120V, 15-amp GFCI duplex
receptacle.

OPERATION

Continued

Note:

If oil level is too low, oil alert system

will keep engine from starting (see Oil Alert
System,
page 6). Make sure oil level is full
before starting. See Engine Oil, page 7.

Before starting the engine, disconnect all
electric loads from generator.

STARTING

IMPORTANT:

The engine speed is preset.

The throttle is locked in preset position. Do
not adjust throttle. Preset position lets en-
gine run at 3600 RPM under load. The
engine must maintain 3600 RPM for gen-
erator to create correct voltage. Running
engine at lower speeds will damage genera-
tor and powered items.

IMPORTANT:

Never start generator with

electrical loads connected. Start engine be-
fore adding electrical loads.

1.

Make sure gasoline tank is full. See
Fuel, page 7 for fuel information.

2.

Move fuel valve lever to the ON posi-
tion except on model MGH3000PR
(see Figure 17).

3.

Move choke lever fully to the left for
all models except MGH3000PR and
MGH10000 (see Figure 17). Pull
choke rod for model MGH3000PR or
choke button for model MGH10000
out (see Figures 18 and 19). This
closes the choke.

Note:

You may not need to close

choke if engine is warm or air tem-
perature is high.

WARNING: Only responsible

adults should use generator.
Never let anyone operate genera-
tor without proper instructions.

PRESTART

Operate generator on a firm, dry, and clean
surface. The surface must be level. Protect
generator from heavy dust, sand, dirt, rain,
or snow. Do not locate generator near stand-
ing water and snow. Make sure area is well-
vented.