POSSIBLE CAUSE

1. Defective capacitor
2. Winding short circuit or loose

connections

3. Defective rotor diode
4. Loss of residual magnetism

1. Engine speed too low

2. Defective rotor diode
3. Partial short circuit in winding

4. Defective capacitor

1. Engine speed too high

1. Defective rotor diode
2. Electrical load too high
3. Engine not running properly

OBSERVED PROBLEM

No voltage when starting generator with no
electrical load

Voltage is less than normal voltage with no
electrical load

Voltmeter reading more than 10% high with
no electrical load

Voltmeter reading correct with no electrical
load, but more than 10% low when electri-
cal load is added

REMEDY

1. Replace capacitor
2. Check resistance of coils (see Electri-

cal Component Specifications, page 15)

3. Replace both diodes on rotor
4. Apply 12-volt battery to capacitor ter-

minals for 2-3 seconds

1. Set engine speed to 3720 RPM (62 Hz)

with no load

2. Replace both diodes on rotor
3. Check resistance of coils (see Electri-

cal Component Specifications, page 15)

4. Replace capacitor

1. Set engine speed to 3720 RPM (62 Hz)

with no load

1. Replace both diodes on rotor
2. Do not overload generator
3. Contact an authorized engine service

center

STORAGE

www.desatech.com

TROUBLESHOOTING

Note:

For additional help, visit DESA

International’s Technical Service web
site at

www.desatech.com

.

Note:

See engine owner’s manual for en-

gine troubleshooting.

IMPORTANT:

Keep generator level while

in storage. Never store generator upside
down or standing on end.

Note:

We supply the engine owner’s manual

with generator. Refer to that manual for
questions concerning engine storage.

WARNING: The muffler be-

comes very hot during operation.
The muffler remains hot for a
while after shutdown. Let engine
cool before storing.

WARNING: Remove all fuel

from fuel tank before storing gen-
erator. Store fuel in approved con-
tainer. Store fuel in a well-vented
area free of open flames or sparks.

Use a fuel additive, such as STA-BIL

®

or an

equivalent, when storing generator with fuel
in fuel tank. This will minimize fuel gum
deposits from forming in engine.

Cover and store generator in a clean, dry
place. Do not expose generator to extreme
high or low temperatures during storage.

SERVICING THE
ENGINE

Honda parts and services should be handled
by your nearest authorized engine service
firm. Check the yellow pages of your tele-
phone directory under the listing:

Engines Gasoline, Honda

TECHNICAL
SERVICE

You may have further questions about as-
sembling, operating, or maintaining this
product. If so, you can visit our Technical
Service web site at

www.desatech.com

or

contact our Technical Service Department
at 1-800-858-8501 (English Only). You may
also write to:

DESA Power Tools™
P.O. Box 90004
Bowling Green, KY 42102-9004
ATTN: Technical Service Power Tools

When contacting DESA Power Tools™,
have ready

• Your Name

• Your Address

• Your Phone Number

• Model Number of Product

• Date of Purchase (Include copy of receipt

for written requests).

Advertising