3 installation description, Installation description, Maintenance – Maretron TMP100 Exhaust Gas Temperature Probe TP-EGT-1 User Manual

Page 12: Troubleshooting, 3 maintenance, 4 troubleshooting, Tmp100 user's manual

Advertising
background image

TMP100 User's Manual

Page 8

Revision

1.0

2.5.5.3 Installation Description…
The TMP100, along with all other Level A certified NMEA 2000 devices, has two user-
programmable installation description fields. You may program these fields with information
specific to the device, such as date installed, the initials/name of the installer, the physical
location of the device, etc. This configuration option will allow you to program the values of
these fields.

3 Maintenance

Regular maintenance is important to ensure continued proper operation of the Maretron
TMP100. Perform the following tasks periodically:

• Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove

paint or markings or may corrode the TMP100 enclosure or seals.

• Ensure that the unit is mounted securely and cannot be moved relative to the mounting

surface. If the unit is loose, tighten the mounting screws.

• Check the security of the cable connected to the NMEA 2000

®

connector, and tighten if

necessary.

• Check the security of all of the probe connections on the top of the unit and tighten if

necessary.

4 Troubleshooting

If you notice unexpected operation of the Maretron TMP100, follow the troubleshooting
procedures in this section to remedy simple problems. If these steps do not solve your
problem, please contact Maretron Technical Support (refer to Section 6 for contact
information).

Symptom

Troubleshooting Procedure

No Temperature data
visible on NMEA 2000

®

network.

Ensure that the TMP100 is properly connected to the NMEA 2000

®

network.

Ensure that the temperature probes are properly connected to the
TMP100.

Ensure that each indicator that you wish to monitor is not
configured as “Disabled”.

Ensure that the TMP100 has the appropriate NMEA 2000

®

PGNs

enabled as described in Section 2.5.6.1.

Incorrect temperature
data

Ensure that the correct type of temperature probe is connected to
the terminals which support that type of temperature probe as
described in Section 2.4.2.

For exhaust gas temperature probes, ensure that the wires are
connected to the TMP100 terminals according to the polarity
specified in Section 2.4.2.1.

Advertising