Table 4-1 S - Registers

Register

Function

Range/units

Default

S0

Auto-answer Ring

0-255 /rings

0

S1

Ring counter

0-255 /rings

0

S2

Escape code character

0-127 /ASCII

43

S3

Carriage return character

0-127 /ASCII

13

S4

Line feed character

0-127 /ASCII

10

S5

Backspace character

0-32, 127 /ASCII

8

S6

Dial tone wait time

2-255 /seconds

2

S7

Remote carrier wait time

1-255 /seconds

50

S8

Comma pause time

0-255 /seconds

2

S9

Carrier detect response time 1-255 /0.1 second

6

S10

Carrier loss time

1-255 /0.1 second

14

S11

Touch-tone dialing speed

50-255 /milliseconds

95

S12

Escape character guard time0-255 /0.02 second

50

S13

Reserved

S14

Echo, response, dialing,

Bit-mapped register

originate/answer

S15

Reserved

S16

Modem tests

Bit-mapped register

0

S17

Reserved

S18

Length of modem tests

0-255 /seconds

0

S19-20 Reserved
S21

CTS, DTR, DCD, DSR and

Bit-mapped register

Long Space Disconnect

S22

Speaker and response

Bit-mapped register

S23

Remote Digital Loopback

Bit-mapped register

Request, data rate, and parity

S24

Sleep mode timer

0-255 seconds

0

S25

Data Terminal Ready delay 0-255 /0.01 second

5

S26

RTS to CTS delay interval

0-255 /0.01 second

1

S27

Asynchronous/Bell/CCITT

Bit-mapped register

Modes

S28

Reserved

S29

Flash time

0-255 /0.01second

0

S30

Disconnect timer

0-255 /10 seconds

0

S31

Autoscan, EC result code

Bit-mapped register

S32

XON character

0-255 /ASCII

17

S33

XOFF character

0-255 /ASCII

19

S34-35 Reserved
S36

LAPM failure options

Bit-mapped register

7

S37

Connection speed

Bit-mapped register

0

S38

Hang-up delay

0-255 /seconds

20

S39

Flow control options

Bit-mapped register

3

S40

MNP options, break types

Bit-mapped register

105

S41

Compression, retrain, DCE Bit-mapped register

3

flow control, block modes

S42-45 Reserved
S46

Data Compression control

136 or 138

138

S47

Reserved

S48

V.42 negotiation options

0, 7, or 128

7

Advertising