Mustek USER'S MANUAL VDC-300 User Manual

Page 38

Advertising
background image

38

Symptom

Cause

Solution

Power Supply

Blurry or out of focus

Distance from subject is not correct.

Refer to the Specifications/Focus Range for

details.

No Power

1. Batteries not loaded correctly

2. Dead batteries

3. Wrong AC adapter

1. Reinstall batteries

2. Replace batteries

3. Use only recommended AC adapter

Sudden power failure

1. Low battery power

2. Auto Power Off function engaged

1. Replace batteries

2. Turn power back on

No capture when

shutter is pressed

1. Operation Mode Selector set to

Playback mode.

2. Memory is full.

1. Set Operation Mode Selector to Camera mode.

2. Delete images.

Inaccurate color

capture

1. Indoor fluorescent lighting

2. Indoor incandescent lighting

3. Outdoor natural lighting

1. Change White balance to Indoor+ setting.

2. Change White balance to Indoor- setting.

3. Change White balance to Outdoor setting.

** We recommend using Auto White Balance**

Image is too dark

Not enough light

1. Change Iris setting to

(F2.8)

2. Use the flash (see Chapter 2)

Image is too bright

1. Strong direct or reflected light

2. Subject is too close to use flash and

large (F2.8) iris setting

1. Change Iris setting to

(F8.0)

2. Change Iris setting to

(F8.0)

** If using flash and subject is further than 1.2

meters set Iris to

(F2.8) **

Redeye

Reflection of light (flash) off the retina of
the human eye

Change the Flash to 1 of 2 Redeye settings

*On-

*Auto-

Advertising