Port Specific Control

„ Port Enable: enabling the port. This function is co-responding with “Master Enable”

function.

„ Bypass Detection: bypass the detection function. Normally the system will try to

detect the 25k

Ω resistor in an 802.3af compliant PD device. If the PD doesn’t follow

by IEEE 802.3af standard, you can enable this option to skip the detection on PD.

When you enable this function, the system will not perform the 25

Ω resistor

detection for PD and directly transmit the power to PD. This function can be

cooperating with “PD discover R (ohms)” function in System setup & Control section

for non-standard compliant PD device.

[Note] after setting the Bypass Detection function, please unplug and then plug in

the PD device.

„ Bypass Classification: the system will skip the power classification and directly

transmit the power to PD when this function is enabling. Normally the system will try

to classify the 802.3af compliant PD device by checking the current class level. The

following table is a standard current classification level table.

Note: After setting the Bypass Classification function, please unplug and then plug in

the PD device.

Power Device

Power (W)

Classification Current

(mA)

Class

Usage

MIN MAX MIN MAX

0 Default

0.44

12.95

0

4

1 Optional

0.44

3.84

9

12

2 Optional

3.84

6.49

17

20

3 Optional

6.49

12.95

26

30

4

Optional

Reserved for future use

36

44

Table of Power Device Classification Levels