Page 19

Advertising
background image

OM-259 Page 15

2-10. Connecting To 115 Volts AC Duplex Receptacle

Ref. ST-801 380-B

1

115 V 15 A AC Receptacle
RC9

Power is shared between RC9 and
remote 14 receptacle RC8.

2

Circuit Breaker CB1

3

Circuit Breaker CB2

CB1 protects 115 volts ac portion of
RC8 and RC9 from overload.

CB2 protects 24 volts ac portion of
RC8 from overload.

Press button to reset breaker.

1

3

2

2-11. Electrical Service Guide

60 Hertz Models

250 Amp Model

300 Amp Model

Input Voltage

200

230

460

200

230

460

575

Input Amperes At Rated Output

34.5

30

15

38

33

16.5

13

Max Recommended Standard Fuse Or Circuit
Breaker Rating In Amperes

50

45

20

60

50

25

20

Min Input Conductor Size In AWG/Kcmil

8

10

14

8

8

12

14

Max Recommended Input Conductor Length In Feet
(Meters)

116 (35)

100 (31)

157 (48)

105 (32)

139 (42)

221 (67)

223 (68)

Min Grounding Conductor Size In AWG/Kcmil

10

10

14

10

10

12

14

Reference: 1996 National Electrical Code (NEC)

S-0092-J

50 Hertz Models

200 Amp Model

300 Amp Model

Input Voltage

220

380

400

440

520

220

380

400

440

520

Input Amperes At Rated Output

19.1

12

10.5

9.5

8.8

34.5

20

19

17.3

14.6

Max Recommended Standard Fuse Or
Circuit Breaker Rating In Amperes

30

20

15

15

15

50

30

30

25

20

Min Input Conductor Size In AWG/Kcmil

10

14

14

14

14

8

12

12

12

14

Max Recommended Input Conductor
Length In Feet (Meters)

146

(44)

171

(52)

189

(58)

229

(70)

320

(97)

127

(39)

151

(46)

167

(51)

202

(62)

183

(56)

Min Grounding Conductor Size In AWG/
Kcmil

10

14

14

14

14

10

12

12

12

14

Reference: 1996 National Electrical Code (NEC)