Miller Electric R-115 User Manual

Page 19

Advertising
background image

OM-193 471 Page 15

3-11. Connection For Hobart Welding Power Sources With 19-Socket Receptacle

Ref. 802 310 / Ref. 193 749

1

Terminal Block 1T

2

Interconnecting Power Cord

3

Green Lead (Connected To

Ground In Section 3-9)

Connect remaining leads to

terminal block as follows:
A: 115 VAC/Neutral Lead
B: 115 VAC/Hot Lead
C: No Connection
D: Dry Contact Closure w/Respect

To Terminal E Lead
E: 115 VAC/Contact Closure Lead

.

For welding power sources
requiring dry contact closure,

move lead 38 at terminal block

to terminal D.

Secure strain relief clamp around

cord.
Reinstall and secure wrapper to

unit.
Connect remaining end of cord to

welding power source.

Tools Needed:

1

A

B

C

D

E

2

1/4 in

3

J

L

K

V

T

C

P

D

H

G F E

R

S

A

M

B

N

U

.

Make ground lead connections
according to Section 3-9
before

following this procedure.

3-12. Connection For L-TEC Welding Power Sources With 19-Socket Receptacle

Ref. 802 310 / Ref. 193 749

1

Terminal Block 1T

2

Interconnecting Power Cord

3

Green Lead (Connected To

Ground In Section 3-9)

Connect remaining leads to

terminal block as follows:
A: 115 VAC/Neutral Lead
B: 115 VAC/Hot Lead
C: No Connection
D: No Connection
E: 115 VAC/Contact Closure Lead
Secure strain relief clamp around

cord.
Reinstall and secure wrapper to

unit.
Connect remaining end of cord to

welding power source.

Tools Needed:

1/4 in

1

A

B

C

D

E

2

3

U N B

M A

S R

E

F

G

H

D

P C

T V

K

L

J

.

Make ground lead connections
according to Section 3-9
before

following this procedure.

Advertising