OM-193 471 Page 17

3-15. Connection For Lincoln Welding Power Sources With Terminal Strip Connections

Ref. 802 310 / Ref. 193 749

1

Terminal Block 1T

2

Interconnecting Power Cord

3

Green Lead (Connected To

Ground In Section 3-9)

Connect remaining leads to

terminal block as follows:
A: 115 VAC/Neutral Lead
B: 115 VAC/Hot Lead
C: No Connection
D: Dry Contact Closure w/Respect

To Terminal E Lead
E: 115 VAC/Contact Closure Lead

.

For welding power sources
requiring dry contact closure,

move lead 38 at terminal block

to terminal D.

Secure strain relief clamp around

cord.
Reinstall and secure wrapper to

unit.
Connect remaining end of cord to

welding power source.

Tools Needed:

1

A

B

C

D

E

2

1/4 in

3

32 (Black)

31 (White)

GND

4 (Orange)

2 (Red)

.

Make ground lead connections
according to Section 3-9
before

following this procedure.

3-16. Connection For AIRCO Welding Power Sources With Two-Prong Twistlock And 115

Volts AC Receptacles

Ref. 802 310 / Ref. 193 749

1

Terminal Block 1T

2

Interconnecting Power Cord

3

Green Lead (Connected To

Ground In Section 3-9)

Connect remaining leads to

terminal block as follows:
A: 115 VAC/Neutral Lead
B: 115 VAC/Hot Lead
C: No Connection
D: No Connection
E: 115 VAC/Contact Closure Lead
Secure strain relief clamp around

cord.
Reinstall and secure wrapper to

unit.
Connect remaining end of cord to

welding power source.

Tools Needed:

1/4 in

1

A

B

C

D

E

2

3

.

Make ground lead connections
according to Section 3-9
before

following this procedure.