2 device label, 3 advanced configuration, 1 restore factory defaults – Maretron NETWORK BUS EXTENDER NBE100 User Manual

Page 10: 3 maintenance, 4 troubleshooting, Device label, Advanced configuration, Restore factory defaults, Maintenance, Troubleshooting

Advertising
background image

NBE100 User's Manual

Page 6

Revision 1.0

2.5.2 Device Label

Program this parameter with a text string which identifies this particular NBE100, to allow you
to easily distinguish it from other NBE100’s on the network.

2.5.3 Advanced Configuration…

Certain parameters do not normally need to be set in order for normal operation, but are
included in an advanced configuration section for use in special situations.

2.5.3.1 Restore Factory Defaults

Selecting this configuration option causes all stored parameters in the NBE100 to be reset to
the values they contained when the unit was manufactured.

3 Maintenance

Regular maintenance is important to ensure continued proper operation of the Maretron
NBE100. Perform the following tasks periodically:

• Clean the unit with a soft cloth. Do not use chemical cleaners as they may remove

paint or markings or may corrode the NBE100 enclosure or seals. Do not use any
cleaners containing acetone, as they will deteriorate the plastic enclosure.

• Ensure that the unit is mounted securely and cannot be moved relative to the mounting

surface. If the unit is loose, tighten the mounting screws.

• Check the security of the cables connected to the NMEA 2000

®

connector, and tighten if

necessary.

4 Troubleshooting

If you notice unexpected operation of the Maretron NBE100, follow the troubleshooting
procedures in this section to remedy simple problems. If these steps do not solve your
problem, please contact Maretron Technical Support (refer to Section 6 for contact
information).

Symptom

Troubleshooting Procedure

No devices on one side
of the NBE100 are
visible from a display
connected to the other
side.

• Ensure that the NBE100 is properly connected to the NMEA

2000

®

network segments.

• Ensure that both NMEA 2000 network segments have

power.

• Ensure that both NMEA 2000 network segments have two

termination resistors fitted.


Advertising